D83.30-A039-78
1 | Refrigerant line | 3 | Refrigerant compressor | 5 | Connecting flange | ||
2 | Screw | 4 | Nut |
Danger | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
Notes on handling refrigerant R1234yf | |||
| Remove/install | ||
1 | Discharge air conditioning system. | ||
2 | Raise vehicle. | ||
Topical note | Special instructions for lifting and supporting vehicle | ||
3 | Remove lower engine compartment paneling. | Model 907.1/2/6 with code XM1 (Noise abatement measures) | |
4 | Remove bolt (2). | Bolt, refrigerant line to refrigerant compressor | |
5 | Pull refrigerant line (1) out of refrigerant compressor (3) and seal openings with suitable stop plugs. | ||
| Compressor oils (specification 362.1) | ||
Installation: Replace sealing ring and coat with compressor oil. | |||
Record plug | |||
6 | Remove nut (4). | Nut, refrigerant line to connecting flange | |
7 | Pull refrigerant line (1) out of connecting flange (5) and seal openings with suitable stop plugs. | ||
| Compressor oils (specification 362.1) | ||
Installation: Replace sealing ring and coat with compressor oil. | |||
Record plug | |||
8 | Remove refrigerant line (1). | ||
9 | Install in the reverse order. |
129 589 00 91 00
Record plug
Referenced documents
- ah0060n010001ts Special instructions for lifting and supporting vehicle
- ah8330n000301a Notes on handling refrigerant R134a
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ah8330p000302a Notes on handling refrigerant R1234yf
- ar0060d100004ts Determine vehicle lift support points on vehicle for vehicle lift with support arms
- ar6120d1105ts Remove/install lower engine compartment lining
- ar8330d1760ts Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks
- as0000z001001a Risk of death caused by vehicle slipping or toppling off of the lifting platform.
- as8300z000601a Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts
- as8300z000701a Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when
- bb0040p036201a Compressor oils (specification 362.1)