AR83.30-D-5445B | Remove/install refrigerant pressure sensor | 20.10.09 |
MODEL 906.6 /7 with CODE (H08) High-performance air conditioning
D83.50-1290-06
1 Electrical connector
B12/6 Roof refrigerant pressure sensor
| Removing | ||
Danger! | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
1 | Discharge air conditioning system | ||
2 | Remove paneling of condenser unit | ||
3 | Disconnect electrical connector (1) at roof refrigerant pressure sensor (B12/6) | ||
4 | Remove roof refrigerant pressure sensor (B12/6) from connector of drier | ||
5 | Close off openings at refrigerant lines using stop plugs | | |
| Install | ||
6 | Remove stop plugs at openings of refrigerant lines | | |
7 | Screw roof refrigerant pressure sensor (B12/6) into connector of accumulator | | |
8 | Connect electrical connector (1) to roof refrigerant pressure sensor (B12/6) | ||
9 | Replace fluid reservoir | After completing the work at the open refrigerant circuit, the accumulator must be replaced. | |
10 | Evacuate air conditioning system, charge it, and then check system to make sure that it functions correctly and does not leak | ||
11 | Install condenser unit paneling |
Air conditioning system
Number | Designation | Model | ||
BA83.30-N-1017-01F | Pressure sensor to drier | Nm | 10 | |
Set of stop plugs
129 589 00 91 00
Referenced documents
- ar8330d1760we Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks
- ar8350d5000b Remove/install condenser unit paneling
- ar8350d5080b Remove/install the air conditioning's fluid reservoir (roof equipment)
- as6500z000201a Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area.