Remove/install actuator motor for fresh and recirculated air flaps

Type ar · topic 83.10 · version 0100 · 2005-07-12

Applies to: MODELS NMB613.367 with CODE (HKG) Konvekta ACX 623 air conditioning with roof heater

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 613 (models 367)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 613 (models 367)

AR83.10-T-2001CA

Remove/install actuator motor for fresh and recirculated air flaps

14.1.05

MODELS NMB613.367 with CODE (HKG) Konvekta ACX 623 air conditioning with roof heater

Remove/install actuator motor for fresh and recirculated air flaps

T83.10-0028-06

1 Split pin

2 Bolt

3 Nut

4 Electrical connector

5 Actuator motor

Remove/install

Danger!

Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area.

AS65.00-Z-0002-01A

1

Move air recirculation flaps for passenger compartment ventilation to recirculation position

See Konvekta air conditioning operating instructions.

2

Switch off ignition

3

Remove roof air conditioning paneling

AR83.50-T-5010CA

4

Remove air duct

Remove only on side in question.

AR83.50-T-4000-01BAS

5

Remove cotter pin (1).

6

Disconnect electrical connector (4)

7

Unscrew bolts (2) from the actuator motor (5)

Hold nuts (3).

8

Remove actuator motor (5)

9

Install in the reverse order