ar8310t2001bac

Remove/install actuator motor for fresh and recirculated air flaps

Type ar · topic 83.10 · version 0100 · 2005-07-12

Applies to: MODELS NMB613.358 /388 with CODE (HKD) Konvekta ACX 640 air conditioning with roof heater MODELS NMB613.455 with CODE (HKE) Konvekta ACX 642 air conditioning with roof heater

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 613 (models 358, 388, 455)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 613 (models 358, 388, 455)

AR83.10-T-2001BAC

Remove/install actuator motor for fresh and recirculated air flaps

24.11.04

MODELS NMB613.358 /388 with CODE (HKD) Konvekta ACX 640 air conditioning with roof heater

MODELS NMB613.455 with CODE (HKE) Konvekta ACX 642 air conditioning with roof heater

Remove/install actuator motor for fresh and recirculated air flaps

T83.10-0027-11

1 Split pin

2 Bolt

3 Nut

4 Electrical connector

5 Actuator motor

Remove/Install

1

Set air recirculation flaps for passenger compartment ventilation into recirculated air position

See Konvekta operating instructions.

2

Switch off ignition

3

Remove air recirculation filter for passenger compartment ventilation

Installation: Check function of air recirculation flap before installing the air recirculation filter.

Clean air recirculation filter for passenger compartment ventilation

AP83.30-T-8338BAC

4

Disconnect electrical connector (4)

5

Remove cotter pin (1).

Installation: Use new cotter pin (1).

6

Loosen screw (2)

Hold nuts (3).

7

Remove actuator motor (5)

8

Install in the reverse order

Referenced documents