AR83.10-T-2001BAC | Remove/install actuator motor for fresh and recirculated air flaps | 24.11.04 |
MODELS NMB613.358 /388 with CODE (HKD) Konvekta ACX 640 air conditioning with roof heater
MODELS NMB613.455 with CODE (HKE) Konvekta ACX 642 air conditioning with roof heater
T83.10-0027-11
1 Split pin
2 Bolt
3 Nut
4 Electrical connector
5 Actuator motor
| Remove/Install | ||
1 | Set air recirculation flaps for passenger compartment ventilation into recirculated air position | See Konvekta operating instructions. | |
2 | Switch off ignition | ||
3 | Remove air recirculation filter for passenger compartment ventilation | Installation: Check function of air recirculation flap before installing the air recirculation filter. | |
| Clean air recirculation filter for passenger compartment ventilation | ||
4 | Disconnect electrical connector (4) | ||
5 | Remove cotter pin (1). | Installation: Use new cotter pin (1). | |
6 | Loosen screw (2) | Hold nuts (3). | |
7 | Remove actuator motor (5) | ||
8 | Install in the reverse order |
Referenced documents
- ap8330t8338bac Clean air recirculation filter for passenger compartment ventilation