AR83.10-S-2500A | Removing and installing control cables from heater/ventilation control unit | 10.4.96 |
MODEL 638.0 /1 /2
S83.10-2005-06
1 Clamp
2 Control cable
3 Clamp
4 Control cable
| Removal, installation | ||
1 | Remove instrument panel | Only to remove control cable (2) | |
2 | Unclip clips and unhook control cables (2) and (4) from heater/ventilation control unit | Remove control unit for heater/ventilation. | |
3 | Remove clamp (1) and unhook control cable (2) from defrosting diffuser. | ||
4 | Remove clamp (3) and unhook control cable (4) from gate for the interior air diffuser. | ||
5 | Remove control cables (2) and (4) | ||
6 | Reinstall in opposite order | Check carefully if the two gates open or close completely when the control cables are activated. |
Referenced documents
- ar6810s1000a Removing and installing instrument panel
- ar8320s1835a Removing and installing switch unit for heater/ventilation