ar8310p2015h

Remove and install left center nozzle air flap actuator motor

Type ar · topic 83.10 · version 0105 · 2006-12-12

Applies to: MODEL 240 Frontklimaanlage

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 240

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 240

AR83.10-P-2015H

Remove and install left center nozzle air flap actuator motor

24.8.06

MODEL 240
Frontklimaanlage

Remove and install left center nozzle air flap actuator motor

P83.10-2327-06

1 Jacket tube

2 Instrument panel carrier

3 Bolt

4 Retaining plate

5 Bolt

6 Electrical connector

M2/12 Left center outlet flap actuator motor

Remove/install

Notes on carrying out repair work in the vehicle interior

AH68.00-P-0001-01H

1

Remove instrument panel

Place instrument panel on a suitable surface.

AR68.10-P-1000H

2

Detach side air duct bracket on the jacket tube (1) and remove the air ducts in the footwell

3

Remove jacket tube (1) from instrument panel carrier (2)

When lowering the jacket tube (1) protect the floor mat in the footwell, otherwise the floor mat may become dirty.

AR68.10-P-1111-01H

Lower bolt for jacket tube on cross member below instrument panel

*BA46.10-P-1001-03H

Upper bolt for jacket tube on cross member below instrument panel

*BA46.10-P-1002-03H

Bolt, reinforcement brace of jacket tube to body

*BA46.10-P-1003-03H

4

Unscrew bolts (3) and remove retaining plate (4)

5

Unscrew bolt (5).

6

Remove left center air outlet flap actuator motor (M2/12) and disconnect electrical connector (6)

7

Install in the reverse order

Jacket tube

Number

Designation

Model
240

BA46.10-P-1001-03H

Lower bolt, jacket tube to cross member below instrument panel

Nm

20

BA46.10-P-1002-03H

Upper bolt, jacket tube to cross member below instrument panel

Nm

20

BA46.10-P-1003-03H

Bolt, jacket tube reinforcement brace to body

Nm

20

Referenced documents