P83.10-2211-06
Illustrated on the removed AC housing
1 Electrical connector
M16/16 Right footwell flap actuator motor
| Remove/install | ||
1 | Remove instrument panel | ||
2 | Disconnect electrical connector (1) from right footwell flap actuator motor (M16/16) | ||
3 | Remove right footwell flap actuator motor (M16/16) from AC housing | Installation: Check condition of adjusting mechanism. If damaged, replace with corresponding part from kinematics parts kit. | |
| Instructions for installing actuator motors | ||
4 | Install in the reverse order | ||
5 | Read out fault memory, delete if necessary and normalize right footwell flap actuator motor (M16/16) | ||
| Connect STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ah8310p000101r Instructions for installing actuator motors
- ar6810p1000r Remove/install dashboard