AR83.10-P-2007QA | Remove/install right footwell flap actuator motor | 22.5.03 |
MODEL 209.4 with CODE (581b) Convenience automatic air conditioning
P83.10-2359-09
1 Bolts
2 Vapor barrier
3 Electrical connector
M2/11 Right footwell flap actuator motor
4 Screw
5 Cable duct
Modification notes
| Removal/installation | ||
1 | Remove cross member under instrument panel | ||
2 | Remove damping (2) | ||
3 | Remove bolts (1) | ||
4 | Detach right footwell flap actuator motor (M2/11) | ||
5 | Separate electrical connection (3) | ||
6 | Install in the reverse order | ||
7 | Connect STAR DIAGNOSIS, normalize right footwell flap actuator motor (M2/11), read out and erase fault memory | ||
| Connect STAR DIAGNOSIS and read out fault memory | ||
Diagnosis system STAR DIAGNOSIS | |||
8 | Perform function check |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ar6810p1120qa Remove/install cross member below instrument panel