ar8310p2003tx

Remove and install right blending air actuator motor

Type ar · topic 83.10 · version 0101 · 2019-03-12

Applies to: Model 219.3

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 219 (models 3**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 219 (models 3**)

AR83.10-P-2003TX

Remove and install right blending air actuator motor

08.03.2019

Model

219.3

Remove and install right blending air actuator motor

1

Electrical connector

2

Bolts

3

AC housing

M2/7

Right blending air flap actuator

P83.10-2459-04

Remove/install

1

Remove top part of dashboard

AR68.10-P-1020TX

2

Disconnect electrical connection (1)

3

Unscrew screws (2) as well as hidden screw (arrow) and remove right air mixing flap actuator motor (M2/7) from air conditioner housing (3)

Instructions for installing actuator motors

AH83.10-P-0001-01R

Installation: Check the condition of the adjustment mechanism for the right air mixing flap. When the right air mixing flap actuator motor (M2/7) is replaced, the position of the right air mixing flap drive shaft must be matched to the position of the actuator drive on the right air mixing flap actuator motor (M2/7).

4

Install in the reverse order

5

Synchronize the actuator motors

Connect STAR DIAGNOSIS and read out fault memory

AD00.00-P-2000-04TX

Menu item, Actuation, Normalization of actuator motors.

Referenced documents