AR83.10-P-2003PP | Remove and install right blending air actuator motor | 9.6.06 |
MODEL 203, 209 with CODE (581) Comfort automatic air conditioning
P83.40-2247-09
1 Bolts
3 Electrical connector
M2/7 Right blend air flap actuator
4 Spring
5 Blower housing
Modification notes
| Remove/install | ||
1 | Remove air conditioner housing | Model 203 | |
Model 209 | |||
2 | Remove tensioning springs (4) | ||
3 | Remove blower housing (5) from air conditioner housing | ||
4 | Remove bolts (1) | ||
5 | Remove right blend air flap actuator motor (M2/7) | ||
6 | Disconnect electrical connector (3) | ||
7 | Install in the reverse order | ||
8 | Connect STAR DIAGNOSIS, normalize right blend air flap actuator (M2/7), read out and erase fault memory | ||
| Connect STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system | |||
9 | Carry out function check |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ar8330p5200p Remove/install air conditioner housing
- ar8330p5200p
- ar8330p5200q Remove/install air conditioner housing