ar8310p2001w

Remove/install actuator motor for fresh and recirculated air flaps

Type ar · topic 83.10 · version 0100 · 2011-03-04

Applies to: MODEL 172.4

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 172 (models 4**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 172 (models 4**)

AR83.10-P-2001W

Remove/install actuator motor for fresh and recirculated air flaps

17.2.11

MODEL 172.4

Remove/install actuator motor for fresh and recirculated air flaps

P83.10-2804-06

1 Bolts

2 Electrical connector

A32 AC housing

M2/5 Fresh air/air recirculation flap actuator motor

Remove/install

1

Remove glove box

2

Unscrew bolts (1) and remove fresh air/recirculated air flap actuator motor (M2/5) from air conditioner housing (A32)

Installation: Install fresh air/recirculated air flap actuator motor (M2/5) on guide pin (arrow) on air conditioner housing (A32).

3

Disconnect electrical connector (2) from fresh air/recirculated air flap actuator motor (M2/5)

4

Install in the reverse order

5

Connect Star Diagnosis and normalize fresh air/recirculated air flap actuator motor (M2/5)

AD00.00-P-2000-04A

Referenced documents