AR83.10-P-2001V | Remove/install actuator motor for fresh and recirculated air flaps | 27.11.03 |
MODELS 171.4
P83.10-2381-06
Shown on the removed heater, AC housing
1 Electrical connector
2 Bolts
3 Relay lever
4 Heater/AC housing
5 Adapter
M2/5 Fresh air and recirculated air flap actuator motor
| Remove/Install | ||
1 | Move front passenger seat to end position toward rear | See Operating Instructions | |
2 | Remove glove compartment | ||
3 | Disconnect electrical connector (1). | ||
4 | Unscrew bolts (2) | ||
5 | Loosen fresh air/recirculated air flap actuator motor (M2/5) from relay lever (3) using an appropriate screwdriver and remove | The relay lever (3) remains mounted to the heater, AC housing (4). | |
Installation: Ensure proper position of the fresh air/recirculated air flap actuator motor (M2/5) at the relay lever (3). | |||
6.1 | Disconnect adapter (5) from fresh air/recirculated air flap actuator motor (M2/5) | When installing a new fresh air/recirculated air flap actuator motor (M2/5). | |
Installation: Observe positioning of toothing (arrows) for adapter (5) and for fresh air/recirculated air flap actuator motor (M2/5). | |||
7 | Install in the reverse order | ||
8 | Synchronize the actuator motors | Menu item, Actuation, Normalization of actuator motors | |
| Connect STAR DIAGNOSIS, read out fault memory | ||
Diagnosis system STAR DIAGNOSIS |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ar6810p1400v Remove/install glove box