ar8310p2001v

Remove/install actuator motor for fresh and recirculated air flaps

Type ar · topic 83.10 · version 0100 · 2006-07-26

Applies to: MODELS 171.4

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 171 (models 4**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 171 (models 4**)

AR83.10-P-2001V

Remove/install actuator motor for fresh and recirculated air flaps

27.11.03

MODELS 171.4

Remove/install actuator motor for fresh and recirculated air flaps

P83.10-2381-06

Shown on the removed heater, AC housing

1 Electrical connector

2 Bolts

3 Relay lever

4 Heater/AC housing

5 Adapter

M2/5 Fresh air and recirculated air flap actuator motor

Remove/Install

1

Move front passenger seat to end position toward rear

See Operating Instructions

2

Remove glove compartment

AR68.10-P-1400V

3

Disconnect electrical connector (1).

4

Unscrew bolts (2)

5

Loosen fresh air/recirculated air flap actuator motor (M2/5) from relay lever (3) using an appropriate screwdriver and remove

The relay lever (3) remains mounted to the heater, AC housing (4).

Installation: Ensure proper position of the fresh air/recirculated air flap actuator motor (M2/5) at the relay lever (3).

6.1

Disconnect adapter (5) from fresh air/recirculated air flap actuator motor (M2/5)

When installing a new fresh air/recirculated air flap actuator motor (M2/5).

Installation: Observe positioning of toothing (arrows) for adapter (5) and for fresh air/recirculated air flap actuator motor (M2/5).

7

Install in the reverse order

8

Synchronize the actuator motors

Menu item, Actuation, Normalization of actuator motors

Connect STAR DIAGNOSIS, read out fault memory

AD00.00-P-2000-04A

Diagnosis system STAR DIAGNOSIS

*WH58.30-Z-1048-13A

Commercially available tools

Number

Designation

WH58.30-Z-1048-13A

STAR DIAGNOSIS diagnosis system, Compact Passenger Car

6511 1801 00

Referenced documents