ar8310p2001qq

Remove/install actuator motor for fresh and recirculated air flaps

Type ar · topic 83.10 · version 0200 · 2006-07-26

Applies to: MODEL 209 with CODE (581b) Convenience automatic air conditioning

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 209

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 209

AR83.10-P-2001QQ

Remove/install actuator motor for fresh and recirculated air flaps

22.8.01

MODEL 209 with CODE (581b) Convenience automatic air conditioning

Remove/install actuator motor for fresh and recirculated air flaps

P83.10-2253-09

1 Bolts

2 AC housing

M2/5 Fresh and recirculated air flap actuator motor

3 Electrical connector

Modification notes

18.2.04

Disconnect/connect/remove ground lead from battery

Remove/Install

1

Remove instrument panel

AR68.10-P-1000Q

2

Remove bolts (1)

3

Remove fresh and recirculated air flap actuator motor (M2/5)

4

Separate electrical connection (3)

5

Install in the reverse order

6

Connect STAR DIAGNOSIS, normalize fresh and recirculated air flap actuator motor (M2/5), read out fault memory and delete

Connect STAR DIAGNOSIS and read out fault memory

AD00.00-P-2000-04A

Diagnosis system STAR DIAGNOSIS

*WH58.30-Z-1048-13A

7

Perform function check

Commercially available tools

Number

Designation

WH58.30-Z-1048-13A

STAR DIAGNOSIS diagnosis system, Compact Passenger Car

6511 1801 00

Referenced documents