ar8310p2001pp

Remove/install actuator motor for fresh and recirculated air flaps

Type ar · topic 83.10 · version 0200 · 2006-06-20

Applies to: MODEL 203 with CODE (581) Comfort automatic air conditioning

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 203

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.30 Blower motor/actuator motor — Series 203

AR83.10-P-2001PP

Remove/install actuator motor for fresh and recirculated air flaps

9.6.06

MODEL 203 with CODE (581) Comfort automatic air conditioning

Remove/install actuator motor for fresh and recirculated air flaps

P83.10-2124-09

Illustrated on model 203.0

1 Bolts

M2/5 Fresh air/air recirculation flaps actuator motor

3 Clutch

Modification notes

11.5.06

"Disconnect/connect ground line on battery" removed

Remove/install

1

Remove instrument panel

AR68.10-P-1000P

2

Remove bolts (1)

Three bolts.

Torx bit set

*000589011000

3

Remove fresh air/air recirculation flap actuator motor (M2/5) from AC housing

4

Disconnect connector (3) from fresh/air recirculation flaps actuator motor (M2/5)

5

Install in the reverse order

6

Synchronize fresh/air recirculation flaps actuator motor (M2/5)

STAR Diagnosis tool.

Remove/install actuator motor for fresh and recirculated air flaps

Torx bit set

000 589 01 10 00