AR83.10-P-2001AK | Remove/install actuator motor for fresh and recirculated air flaps | 24.3.04 |
Model 169.0 /3, 245.2
P83.10-2510-06
Illustrated on model 245.2
1 Bolts
2 Carrier plate
3 Heater or A/C housing
4 Electrical connector
5 Bolts
6 Power adapter
M16/21 Fresh air/air recirculation flap actuator motor
(with code (581) Comfort automatic air conditioning)
M16/7 Air recirculation flap actuator
(except code (581) Comfort automatic air conditioning)
| Remove/Install | ||
1 | Remove cover below instrument panel on left | ||
2 | Remove bolts (1) from carrier plate (2) | ||
3 | Remove carrier plate (2) with fresh air/air recirculation flap actuator motor (M16/21) or with air recirculation flap actuator (M16/7) from heater or A/C housing (3) until the electrical connector (4) is accessible | Installation: Ensure that the air recirculation flap is closed before positioning the carrier plate (2) on the heater or A/C housing (3). | |
4 | Disconnect electrical connector (4) from fresh air/air recirculation flap actuator motor (M16/21) or from air recirculation flap actuator (M16/7) | ||
5.1 | Remove bolts (5) using cordless drill/driver and remove fresh air/air recirculation flap actuator motor (M16/21) or air recirculation flap actuator (M16/7) from carrier plate (2) | When replacing the fresh air/air recirculation flap actuator motor (M16/21) or the air recirculation flap actuator (M16/7). | |
Rechargeable battery-powered drill/screwdriver | |||
6.1 | Remove power adapter (6) from fresh air/air recirculation flap actuator motor (M16/21) or air recirculation flap actuator (M16/7) | When replacing the fresh air/air recirculation flap actuator motor (M16/21) or the air recirculation flap actuator (M16/7). | |
7 | Install in the reverse order | ||
8 | Synchronize the actuator motors | Menu item, Actuation, Normalization of actuator motors. | |
| Connect STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system |
Commercially available tools
Referenced documents
- ad0000p200004ak Connect STAR DIAGNOSIS and read out fault memory
- ar6810p1500ak Remove/install cover below instrument panel (left)