AR83.10-P-0100SO | Remove/install air recirculation unit | 1.10.02 |
MODEL 450.3## /4## (except , 450.418) 1#
with CODE (I01) Air conditioning Plus (with outside temperature indicator) (FFO)
with CODE (I29) Air conditioning Plus (with combination filter and outside temperature indicator), smart & passion
P83.10-2343-09
Shown on model 450.3
1 Air recirculation box
2 Electrical connector
3 Bracket
4 Recirculated air cable
8 Lever
N26 EDW control unit
5 Electrical connector
6 Nut
7 Catch
| Remove/install | ||
1 | Remove expansion valve | ||
2 | Remove right sound converter box | ||
3 | Remove electrical connector (2) from bracket (3) and disconnect | ||
4 | Unhook recirculated air cable (4) from air recirculation unit (1) | Installation: Insert recirculated air cable (4) in catch (7) and latch in place on lever (8). Adjust recirculated air cable (4): | |
Detach recirculated air cable (4) from catch (7) on lever (8) of air recirculation unit (1). Push heater/ventilation operating unit lever all the way upward and hold. Push lever (8) on air recirculation unit (1) all the way to the left and lock recirculated air cable (4) covering. | |||
5.1 | Disconnect plug and socket connection (5) | On vehicles with alarm system (relevant for service), code V02. | |
6.1 | Unscrew nuts at bottom of firewall and remove ATA [EDW] control unit (N26) | On vehicles with alarm system (relevant for service), code V02. | |
7 | Unscrew nut (6) at top and bottom of firewall | ||
8 | Remove air recirculation unit (1) | ||
9 | Install in the reverse order | ||
10 | Carry out function test |
Referenced documents
- ar8260p1100sn Remove/install sound converter box
- ar8330p5520sm Remove/install expansion valve