AR83.10-L-2001VA | Remove/install actuator motor for fresh and recirculated air flaps | 20.8.01 |
MODEL 414.700
L83.10-0006-06
1 Air duct
2 Screw
3 Fresh air/recirculated air flap actuator motor connector
4 Cam
M16/7 Fresh air/recirculated air flaps actuator motor
| Remove/install | ||
1 | Remove instrument panel | ||
2 | Unclip air duct (1) | Note correct installation positions. | |
3 | Disconnect fresh air/recirculated air flap actuator motor (M16/7) | ||
4 | Remove fresh air/recirculated air flap actuator motor (M16/7) | Installation: The fresh air/recirculated air flap actuator motor (M16/7) should engage in the hexagonal shaft on the | |
5 | Install in the reverse order | ||
6 | Check fresh air/recirculated air flap actuator motor for proper function | Ensure that air flaps open and close completely. |
Referenced documents
- ar6810l1000va Remove/install instrument panel