ar8310d1200a

Remove/install blower regulator

Type ar · topic 83.10 · version 0101 · 2011-07-08

Applies to: MODEL 900, 906.1 /2 /6 /7

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 900 · Series 906 (models 1**, 2**, 6**, 7**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.11 Control unit/relay — Series 900 · Series 906 (models 1**, 2**, 6**, 7**)

AR83.10-D-1200A

Remove/install blower regulator

28.6.11

MODEL 900, 906.1 /2 /6 /7

Remove/install blower regulator

D83.10-1123-09

1 Plug for connection line

R14 Blower motor series resistor group

Remove/install

1

Remove glove box

AR68.10-D-1400A

2

Remove plug for connection line (1)

3

Rotate blower motor series resistor group (R14)
far enough in clockwise direction, until the blower motor series resistor group (R14)
is released from the air duct

4

Remove blower motor series
resistor group (R14)

5

Install in the reverse order

Referenced documents