AR83.10-D-0010NA | Remove ventilation box | 8.2.01 |
MODELS WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7
MODELS 903.61 /66 /67, 904.61 /66 with CODE (ZU7) National version for Canada
MODELS 903.61 /66 /67, 904.61 /66 with CODE (ZU8) National version for USA
MODELS 903.61 /62 /66 /67, 904.61 /62 /66 with CODE (ZU9) National version for Mexico
D83.10-1103-06
1 Ventilation box
2 Pollen filter cover
3 Vacuum line
4 Nut
5 Washer
6 Connector
7 Connector
8 Connector
9 Connector
| Remove/Install | ||
1 | Prepare ventilation box for removal | ||
2 | Release clamps and remove pollen filter cover (2) | Remove pollen filter if necessary. | |
3 | Disconnect vacuum line (3) from left ventilation box | ||
4 | Unscrew ventilation box (1) and gently pull off | Unscrew 5 nuts (4) and remove together with washers (5) | |
5 | Disconnect connectors (6 and 7) and disconnect plugs (8 and 9) | ||
6 | Install in the reverse order |
Referenced documents
- ar8310d001002a Prepare ventilation box for removal