Marker lamp removal and installation procedure |
108 | Marker lamp unit |
109 | Marker lamp electrical connector E13.1, E13.2 / E12.1, E12.2 |
Y82.10-0005-06
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove/install | ||
1 | Switch off ignition | ||
2 | Disconnect ground line of battery | ||
3 | Remove marker lamp unit (108) from cabin | ||
4 | Disconnect marker lamp electrical connector E13.1, E13.2 / E12.1, E12.2 (109) from marker lamp | ||
5 | Install in the reverse order |
Referenced documents
- ah5410p000101a Notes on battery
- ah5410p000101a
- as5410z000101a Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of