1 | Cover |
2 | Bolts |
D80.20-1165-02
3 | Cable tie |
4 | Electrical connectors |
M14/27m1 | Right sliding door ZV motor |
D80.20-1169-11
5 | Nut |
6 | Bolts |
7 | Sliding door lock |
D80.20-1168-02
Danger ! | Risk of injury. Moving parts can pinch, crush or, in extreme cases even sever extremities. | No parts of the body or limbs should be within the operating area of mechanical components when moving components. | |
| Remove/install | ||
1 | Unscrew bolts (2) | ||
2 | Take off cover (1) | Install cover (1) only after function test. | |
3 | Cut cable ties (3) from right sliding door CL motor (M14/27m1) and disconnect electrical connectors (4) | Insulate uninsulated connectors. | |
4 | Remove bolts (6) | Installation: Secure bolts (6). | |
Thread locking agent, Loctite 243 (10 ml) | |||
5 | Unscrew nut (5) and remove sliding door lock (7) | Installation: Secure nut (5). | |
Thread locking agent, Loctite 243 (10 ml) | |||
6.1 | Remove microswitch from right sliding door CL motor (M14/27m1) | Screwed version | |
Installation: Replace microswitch with bracket. | |||
Thread locking agent, Loctite 243 (10 ml) | |||
6.2 | Remove microswitch from right sliding door CL motor (M14/27m1) | Riveted version | |
Installation: Replace microswitch with bracket. | |||
Thread locking agent, Loctite 243 (10 ml) | |||
7.1 | Remove microswitch from door lock | Screwed version | |
Installation: Replace microswitch with bracket. | |||
Thread locking agent, Loctite 243 (10 ml) | |||
Bolt, door lock to door locking system | |||
7.2 | Remove microswitch from door lock | Riveted version | |
Installation: Replace microswitch with bracket. | |||
Thread locking agent, Loctite 243 (10 ml) | |||
Bolt, door lock to door locking system | |||
8 | Install in the reverse order | ||
| Check | ||
9 | Check adjustment of door lock and adjust |
Referenced documents
- ar7216d403501a Check adjustment of sliding door lock and adjust
- ar8020d010201b Remove/install microswitch on central locking motor
- ar8020d010201d Remove/install microswitch on central locking motor
- ar8020d010202b Remove/install microswitch on door lock
- ar8020d010202d Remove/install microswitch on door lock
- as0000z000901a Risk of injury. Moving parts can pinch, crush or, in extreme cases even sever extremities.