AR77.50-P-4400A | Checking, adjusting gap between hard top and windshield molding strip | 16.3.10 |
MODEL 129
P77.30-0296-01
P77.30-0297-01
P77.30-0298-01
Figure 1
Dimension A = approx. 6 mm
Figure 3
Figure 2
Dimension B = approx. 6 mm
P77.30-0299-01
Figure 4
1 Bolt
2 Rail
3 Long wedge
Figure 5
P77.30-0300-01
| Inspecting | ||
1 | Check gap (A) between hard top and windshield molding strip in area of lock pins, adjust if applicable | For dimension A see figure 1. | |
2 | Check distance (B) from A-pillar rail to rail on side of hard top, if applicable adjust rail at hard top | For dimension B see figure 2. | |
3 | Check transition for seals in area of separating joint between A-pillar and hard top. | The sealing lip on the A-pillar should extend approx. 1 mm over the seal on the hard top. When the window is closed the separating joint is covered by the lip. Correct seals, if applicable | |
4 | Unlock hard top and shim cross member above windshield | Use suitable shim | |
5 | Unscrew screw (1) from hard top | ||
6 | Shim rail (2) | Long wedge (figure 3) | |
N | Pull seal out at corner of hard top | ||
8 | Press sealant in between seal and hard top (figure 5, arrows) | ||
9 | Install seal and screw on rail | ||
10 | Lock hard top and remove sealant coming out | Use naphtha. |
Long wedge
115 589 03 59 00
Repair materials
Number | Designation | Order number |
BR00.45-Z-1007-02A | Adhesive, windows 310 ml TEROSTAT MS 930 | A 005 989 61 71 |