AR72.40-W-1007A | Remove and install emergency stop valve | 28.10.09 |
MODEL 957.### #Z up to 930156 with BODY 957.810
with folding door, Ikarus
W72.40-1053-06
1 EMERGENCY-OFF valve
2 Emergency cock
3 Compressed-air line
4 Compressed-air line
5 Angle connection fitting
6 Connection fitting
Modification notes
| Remove/install | ||
Danger! | Risk of injury from pinching and crushing when working on the folding door and the folding door control system | When working on the folding door or folding door control, relieve pressure from system with emergency lever (off position). | |
1 | Remove grab bar | ||
2 | Remove paneling from folding door control | ||
3 | Remove angle connection fitting (5) from EMERGENCY OFF valve (1) | ||
4 | Remove connection fitting (6) from EMERGENCY-OFF valve (1) | ||
5 | Remove EMERGENCY-OFF valve (1) | ||
6 | Install in the reverse order |
Referenced documents
- ar6830w0160a Remove, install folding door control paneling
- ar6870w0300a Remove/install support rod
- as7200z000101a Injury hazard! When working on folding door or folding door control body parts can be pinched or crushed