ar7240w1005a

Adjust folding door pressure switch

Type ar · topic 72.40 · version 0200 · 2009-11-16

Applies to: MODEL 957.### #Z up to 930156 with BODY 957.810 with folding door, Ikarus

Where it sits

Function group 3 Body › 72 Doors › 72.40 Door control — Series 957

EinPAS 35 Body/frame/detachable parts › 35.35 Door › 35.35.30 Door drive system/door control — Series 957

EinPAS 35 Body/frame/detachable parts › 35.51 Passenger door 1 › 35.51.12 Sensor/switch/wiring harness — Series 957

EinPAS 35 Body/frame/detachable parts › 35.52 Passenger door 2 › 35.52.12 Sensor/switch/wiring harness — Series 957

EinPAS 35 Body/frame/detachable parts › 35.53 Passenger door 3 › 35.53.31 Door drive system/door control — Series 957

EinPAS 35 Body/frame/detachable parts › 35.54 Passenger door 4 › 35.54.12 Sensor/switch/wiring harness — Series 957

AR72.40-W-1005A

Adjust folding door pressure switch

28.10.09

MODEL 957.### #Z up to 930156 with BODY 957.810
with folding door, Ikarus

Adjust folding door pressure switch

W72.40-1076-06

1 Protective cap

2 Electrical connector

3 Compressed-air connection

4 Adjustment screw (lower shift point)

5 Adjustment disk (upper shift point)

6 Electrical contact

7 Multimeter

S142 Pressure switch 6 bar (closes at 6 bar and opens at 3 bar)

Modification notes

1.8.09

Work procedure completely modified

Removing

Danger!

Risk of injury from pinching and crushing when working on the folding door and the folding door control system

When working on the folding door or folding door control, relieve pressure from system with emergency lever (off position).

AS72.00-Z-0001-01A

1

Remove grab bar

AR68.70-W-0300A

2

Remove paneling from folding door control

AR68.30-W-0160A

3

Remove 6 bar pressure switch ( (S142) from folding door

AR72.40-W-1004A

4

Remove protective cap (1).

5

Remove electrical connector (2) from 6 bar pressure switch ( (S142)

Adjust

6

Connect compressed air supply line with pressure reducing valve to compressed air connection (3) of 6 bar pressure switch (S142)

Adjust pressure to 0 bar.

7

Connect multimeter (7) to electrical contacts (6) on 6 bar pressure switch (S142)

8

First turn adjustment screw (4), then turn adjustment disk (5) counterclockwise to stop to position "0"

The multimeter (7) must display a reading of more than 30 kΩ.

9

Adjust lower shift point on 6 bars pressure switch (S142)

Adjust pressure to 3 bars, then slowly turn adjustment screw (4) clockwise. The lower shift point is adjusted as soon as the reading drops suddenly below 5 Ω.

*BE72.40-N-1006-01A

10

Check adjusted lower shift point of 6 bar pressure switch (S142)

Increase pressure to over 3 bars.

The reading must increase to over 30 kΩ.

Adjust pressure precisely to 3 bars

The reading must drop below 5 Ω. if necessary:

Again adjust lower shift point on 6 bar pressure switch ( (S142) and check.

11

Preadjust upper shift point on 6 bar pressure switch ( (S142)

Turn adjustment bolt (5) one 3/4 turn clockwise and do not hold adjustment screw (4).

12

Adjust upper shift point on 6 bar pressure switch ( (S142)

Slowly increase pressure to precisely 6 bars. The upper shift point is adjusted correctly, if the reading increases suddenly to a value over 30 kΩ at a pressure of precisely 6 bars, if necessary:

*BE72.40-N-1006-01A

Readjust upper shift point by adjusting adjustment screw (5 )

13

Check function of 6 bar pressure switch ( (S142)

Slowly increase pressure of 0 bar to 6 bars and then slowly lower to 3 bars. Check corresponding readings.

0 bar: Measurement < 5 Ω

6 bars: Measurement >30 kΩ

3 bars: Measurement <5 Ω

if necessary:

Readjust lower and upper shift point on 6 bar pressure switch ( (S142).

14

Remove multimeter (7)

15

Disconnect compressed air supply system from 6 bar pressure switch ( (S142)

Install

16

Install protective cap (1)

17

Install electrical connector (2) on 6 bar pressure switch ( (S142)

18

Install 6 bar pressure switch ( (S142) on folding door

AR72.40-W-1004A

19

Install paneling on folding door control

AR68.30-W-0160A

20

Install retaining rod

AR68.70-W-0300A

Check values for door control

Number

Designation

Model series 957

BE72.40-N-1006-01A

Pressure switch 6 bar (closes at 6 bar and opens at 3 bar) (S142)

Lower switching point

bar

3

Upper switching point

bar

6