4 Inner pillar paneling
7 Emergency hammer holder
T68.30-0013-03
| Removing, installing | ||
1 | Remove emergency hammer and unscrew mounting screws for emergency hammer holder (7) | ||
2 | Carefully detach inner pillar paneling (4) from top downward | The inner pillar paneling is fastened over its entire length with adhesive strips. | |
3 | Remove adhesive strips | Installation: Replace adhesive strips. | |
4 | Install in the reverse order |
Long wedge
115 589 03 59 00
Repair materials
Number | Designation | Order number |
BR00.45-Z-1022-02A | Adhesive tape replaced by: A 005 989 70 85 | A 005 989 29 85 |