1 Emergency hammer mount
2 Coat hook
3 Inner pillar paneling
T67.30-0004-03
| Remove, Install | ||
1 | Remove emergency hammer and unscrew mounting screws from emergency hammer mount (1) | ||
2 | Remove coat hook (2) | The coat hook is fastened with a screw which is concealed with a plastic cap. | |
3 | Carefully loosen inner pillar paneling (3) from top to bottom | The inner pillar paneling is fastened with adhesive tape over the entire length. | |
4 | Remove adhesive strips | Installation: apply fresh adhesive strips. | |
Adhesive tape | |||
5 | Install in the reverse order |
Assembly wedge
115 589 03 59 00
Repair materials
Number | Designation | Order number |
BR00.45-Z-1022-02A | Adhesive tape replaced by: A 005 989 70 85 | A 005 989 29 85 |