ar6510s100002ea

Separate center roof paneling

Type ar · topic 65.10 · version 0100 · 2014-10-01

Applies to: MODEL 447.601/701/811

Where it sits

Function group 3 Body › 65 Roof › 65.10 Roof paneling — Series 447 (models 601, 701, 811)

EinPAS 35 Body/frame/detachable parts › 35.39 Roof › 35.39.30 roof paneling/roof frame — Series 447 (models 601, 701, 811)

AR65.10-S-1000-02EA

Separate center roof paneling

MODEL

447.601/701/811

Separate center roof paneling

1

Expose spot welds on center roof paneling (1) and cut out (areas A and B).


2

Expose laser weld seams on center roof paneling (1) and cut (areas C and D).

S65.10-4593-06

Separate center roof paneling

3

Heat center roof paneling (1) in crosshatched areas.


Cross-hatched areas are bonded.


4

Remove damaged center roof paneling (1).

S65.10-4594-06

Separate center roof paneling

5

Grind mating surfaces down to bare metal in the cross-hatched inner C-pillar sidewall .


Sand down spot weld flanges to bare metal on both sides.


6

Remove shavings and drill chips.


7

Coat insides of spot weld flanges with zinc dust paint.

S65.10-4595-06