S63.20-4733-09
a | Dimension approx. 110 mm | b | Dimension approx. 40 mm | c | Dimension approx.60 mm |
1 | Scribe separating points and cut (areas A and B). |
Do not make the cuts too deep. |
S63.20-4734-09
2 | Expose spot welds on inner A-pillar reinforcement (2) and cut out (areas C to G). |
Cut out spot welds on both sides (area G). |
3 | Bend open sheet metal lug (area G). |
4 | Remove damaged inner A-pillar reinforcement (2). |
5 | Sand down mating surfaces to bare metal in crosshatched areas . |
Sand down spot weld flanges to bare metal on both sides. |
6 | Remove shavings and drill chips. |
7 | Coat insides of spot weld flanges with zinc dust paint. |
S63.20-4735-06