1 | B-pillar outer section |
P63.20-6192-06
1 | B-pillar outer section |
P63.20-6191-05
| Remove | ||
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | General information on body repair | ||
Topical note | Notes on performing repair, body work and welding on vehicles with airbags and RTE units | ||
1 | Remove detachable parts in the repair area | B-pillar outer section (1) can be cut in the areas A to F. | |
2 | Cover all detachable parts remaining in vehicle (area to be repaired) | | |
3 | Remove B-pillar outer section (1) | ||
4 | Prepare connecting points of B-pillar outer section (1) at body | ||
5 | Prepare B-pillar outer section (1) for installation | ||
Notes on replacing body parts | |||
When replacing body panels under B-pillar outer section (1), this area of the B-pillar outer section must be separately treated. | |||
| Install | ||
Danger | The high voltage used for electric welding presents a lethal hazard. Risk of explosion from welding in areas close to highly inflammable materials. Risk of injury from weld splatter and UV-light when welding. Risk of poisoning from inhaling welding gases | Use insulating mats. Wear protective clothing, safety glasses and a protective mask. Remove highly inflammable materials from the hazard area. Use air extraction system. | |
Topical note | Measures for preventing damage to vehicles or components when performing electric welding work | ||
6.1 | Fit B-pillar outer section (1) | Only if no reinforcements or body panels located underneath were replaced. | |
6.2 | Fit B-pillar outer section (1) | Only if reinforcements or body panels located underneath were replaced. | |
7 | Clean weld joints and sheet metal flanges with wire brush and clean repair areas | ||
8 | Prime repair area using primer filler | ||
9 | Supply standard seam seals with body sealant | ||
White sealing compound, 310 ml, DBL 6069.20 | |||
10 | Supplement standard underbody protection with permanent underfloor protection | Underfloor protection 800 ml | |
11 | Paint repair area adjacent surfaces | ||
12 | Supplement hollow cavity preservation after repair work | ||
Teroson protective wax, art. no: 122.73Q | |||
13 | Reinstall all removed assembly parts |
Referenced documents
- ah0000n000501a Measures for preventing damage to vehicles or components when performing electric welding work
- ah6000n000101a General information on body repair
- ah6000p002701ff Notes on replacing body parts
- ah9100p000201m Notes on performing repair, body work and welding on vehicles with airbags and RTE units
- ar6320p112101ff Remove outer section of B-pillar
- ar6320p112102ff Prepare B-pillar outer section
- ar6320p112103ff Install B-pillar outer section
- ar6320p112103fg Install B-pillar outer section
- ar6320p112106ff Prepare connecting points for B-pillar outer section on body
- ar9710p4000ff Seam sealing following repair
- ar9720p1500ff Cavity preservation following repair work
- as0000z000701a The high voltage used for electric welding presents a lethal hazard. Risk of explosion from welding in areas close to highly inflammable materials. Risk of injury from weld splatter and UV-light when welding. Risk of poisoning from
- as0000z001701a Risk of injury caused by scraping or cutting body parts on sharp vehicle parts