D63.10-1416-06
The following operation steps are shown on the left front side wall paneling (1) for model 906.733 and must be performed analogously on the right side if damaged.
1 Scribe separation line on front side wall paneling (1) (area A).
2 Cut front side wall paneling (1) at separation point (area A).
Dimensions:
a approx. 25 mm
3 Drill Ø 7 mm holes in front side wall paneling (1) (area D).
4 Grind crosshatched areas on front side wall paneling (1) down to bare metal around holes.
5 Grind mating surfaces on front side wall paneling (1) down to bare metal in crosshatched areas.
Grind spot weld flanges down to bare metal on both sides.
6 Coat insides of spot weld flanges with zinc dust paint.
D63.10-1420-09
7 Punch Ø 6 mm holes in front side wall paneling (areas B and C).
8 Grind crosshatched areas on front side wall paneling down to bare metal around holes.
9 Grind mating surfaces on front side wall paneling down to bare metal in crosshatched areas.