T55.50-0007-11
1 De-pressure accumulator
T55.50-0043-11
8 Control block
9 Spherical valve
11 Exhaustion valve
| Remove | ||
Danger! | Risk of injuries on skin and eyes when high pressure hydraulic fluid is ejected. Risk of poisoning by ingesting hydraulic fluid | Before starting the jobs on the hydraulic system, leave the system de-pressurized. Wear adequate clothes and protection glasses. | |
1 | Close the spherical valve (9) | ||
2 | Evacuate the hydraulic system pressure | Evacuate the pressure through the ventilation valve (11) of the control block (8). | |
Catch hydraulic fluid run-off, in an appropriate container. | |||
3 | Disconnect the threaded union of the pressure accumulator (1) on the control block (8) | ||
4 | Remove the pressure accumulator (1) | ||
| Install | ||
5 | Install the pressure accumulator (1) | ||
6 | Connect the threaded union of the pressure accumulator (1) to the control block (8) | ||
7 | Open the spherical valve (9) | ||
8 | Bleed the hydraulic system |
Referenced documents
- ar5530b0003a Fill and bleed power hydraulics system
- as0000b001301a Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure.Risk of poisoning from swallowing hydraulic fluid.