AR54.61-T-0003BB | Removing and installing modular tachograph (MTCO) | 16.2.12 |
MODELS NMB671, 613
with modular tachograph (MTCO)
T54.61-0004-01
T54.61-0005-01
T54.61-0006-01
The diagram shows the installation location in model 671
The diagram shows the installation location in model 613.367/368
The diagram shows the installation location in model 613.358/388
W54.61-1009-06
Diagram as an example
1 Extractor hooks
2 Lock
P3 Modular tachograph (MTCO)
T54.61-0007-11
3 Cover
P3 Modular tachograph (MTCO)
| Remove | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnecting and connecting electrical cables from battery | On model 671.000/005/010/312/322/327, 613.355/364/365/455/485 | |
In case of model 671.015/020/021/030/ | |||
For model 613.358/388 | |||
In case of model 613.367 | |||
In case of model 613.368 | |||
| Notes on battery | All models | |
2 | Insert both extractor hooks (1) in the side openings of the modular tachograph (MTCO) (P3) up to the noticeable stop | The lock (2) is unlocked in the process. | |
3 | Pull the modular tachograph (MTCO) (P3) out of the installation opening using the extractor hooks (1) | ||
4 | Detach cover (3) from the back of the modular tachograph (MTCO) (P3) equipment | This operation may only performed by workshop personnel who are authorized to check tachographs. To do this,remove the lead seal on the cover (3) and detach the cover (3) upwards. | |
5 | Detach the connection plug on the back of the modular tachograph (MTCO) (P3) equipment | ||
| Install | ||
6 | Install the connection plug on the back of the modular tachograph (MTCO) (P3) equipment | ||
7 | Install the cover (3) on the back of the modular tachograph (MTCO) (P3) equipment | This operation may only performed by workshop personnel who are authorized to check tachographs. To do this push the cover (3) from above until the lugs latch downwards and attach tamper-proof seal. | |
8 | Insert the modular tachograph (MTCO) (P3) in the installation opening | The modular tachograph (MTCO) (P3) must latch in the installation opening in the lock (2). Observe the manufacturer's operator's manual. | |
9 | Connect electric lines to the battery | On model 671.000/005/010/312/322/327, 613.355/364/365/455/485 | |
In case of model 671.015/020/021/030/ | |||
For model 613.358/388 | |||
In case of model 613.367 | |||
In case of model 613.368 | |||
| Notes on battery | All models |
Commercially available tools
Referenced documents
- ah5410p000101a Notes on battery
- ah5410p000101a
- ar5418t0002aa Disconnecting and connecting electrical cables from battery
- ar5418t0002ba Disconnect electric cables at battery, connect.
- ar5418t0002ca Disconnecting and connecting electrical cables from battery
- ar5418t0002cb Disconnect electric cables at battery, connect
- as5410z000101a Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of