ar5461t0001c

Removing and installing flat tachograph (FTCO)

Type ar · topic 54.61 · version 0102 · 2012-02-23

Applies to: MODEL 613.364 /365

Where it sits

Function group 2 Chassis › 54 Electrical system, equipment and instruments › 54.61 Speed recorder, trip recorder, taximeter — Series 613 (models 364, 365)

EinPAS 31 Communication/information/entertainment › 31.35 Tachograph/toll system › 31.35.40 Tachograph — Series 613 (models 364, 365)

AR54.61-T-0001C

Removing and installing flat tachograph (FTCO)

16.2.12

MODEL 613.364 /365

Removing and installing flat tachograph (FTCO)

T68.10-0016-06

1 Flat tachograph FTCO

5 Speedometer signal cable

6 FTCO connecting cable

9 Fastening point for speedometer signal cable and FTCO connecting cable

Removing, installing

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Disconnect battery

Disconnect negative terminal first.

To do this, unlock battery tray and pull out.

Notes on battery

All models

AH54.10-P-0001-01A

2

Remove instrument panel

Perform only the operations for releasing the instrument panel.

AR68.10-T-1000C

3

Disconnect FTCO cable (6)

Mark the electrical connections on the FTCO flat tachograph (1) for subsequent identification.

The cover on the plug connections is secured with a lead seal.

4

Remove the cable ties from the speedometer signal cable (5)

AR54.61-T-0001-01C

5

Detach speedometer signal cable (5)

6

Remove FTCO flat tachograph (1)

Four Phillips screws hold the FTCO flat tachograph to the instrument panel.

7

Install in the reverse order

8

Calibrate flat tachograph (1) and apply lead seal.

This operation is to be performed solely and exclusively by individuals certified in accordance with Art. 57b of the German licensing regulations.