T68.10-0016-06
1 Flat tachograph FTCO
5 Speedometer signal cable
6 FTCO connecting cable
9 Fastening point for speedometer signal cable and FTCO connecting cable
| Removing, installing | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect battery | Disconnect negative terminal first. To do this, unlock battery tray and pull out. | |
| Notes on battery | All models | |
2 | Remove instrument panel | Perform only the operations for releasing the instrument panel. | |
3 | Disconnect FTCO cable (6) | Mark the electrical connections on the FTCO flat tachograph (1) for subsequent identification. The cover on the plug connections is secured with a lead seal. | |
4 | Remove the cable ties from the speedometer signal cable (5) | ||
5 | Detach speedometer signal cable (5) | ||
6 | Remove FTCO flat tachograph (1) | Four Phillips screws hold the FTCO flat tachograph to the instrument panel. | |
7 | Install in the reverse order | ||
8 | Calibrate flat tachograph (1) and apply lead seal. | This operation is to be performed solely and exclusively by individuals certified in accordance with Art. 57b of the German licensing regulations. |
Referenced documents
- ah5410p000101a Notes on battery
- ah5410p000101a
- ar5461t000101c Releasing and attaching FTCO cable ties
- ar6810t1000c Removing and installing instrument panel
- as5410z000101a Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of