N54.30-8670-09
1 Instrument cluster
2 Control knob
3 Nut
4 Washer
9 Connector
10 Connector
11 Connector
12 Connector
5 Hazard flasher switch
6 Bolts
7 Cover
8 Connector
| Remove/Install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect ground line from battery | ||
| Notes on battery | ||
2 | Detach control knob (2). | ||
3 | Unscrew nut (3) and remove washer (4). | ||
4 | Remove light switch from instrument cluster (1). | Installation: Ensure that light switch is seated correctly in instrument cluster (1). | |
5 | Remove hazard flasher switch (5). | ||
6 | Remove bolts (6). | ||
7 | Pull cover (7) with instrument cluster (1) forward until connectors (8, 9, 10, 11, 12) are accessible. | ||
8 | Unplug connectors (8, 9, 10, 11, 12). | ||
9 | Unclip instrument cluster (1) from cover (7). | Installation: Ensure cover (7) is seated correctly in instrument cluster (1). | |
10 | Install in the reverse order | ||
11 | Check that instrument cluster (1) functions correctly. |