Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Caution | Risk of injury caused by burns to skin and eyes, risk of poisoning caused by inhaling fumes during soldering. | Wear protective gloves, protective clothing and safety glasses. Ensure that the work area is adequately ventilated. Secure power supply cables. Avoid sources of fire in working area. | |
Caution | Risk of injury caused by burns to skin and eyes. Risk of poisoning caused by inhaling fumes when working with heat-shrinkable tubing. | Work in well ventilated rooms only. Wear safety glasses with side protection and protective gloves. | |
Topical note | Notes on replacement of safety-relevant and special components | ||
Topical note | Notes on soldering | ||
Topical note | Assessment of damage in wiring harnesses | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on cable protection | |||
Notes on safety-relevant components | |||
Advantages of repairing wiring harnesses | |||
Notes on soft soldering | |||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove | ||
1 | Remove detachable parts in the repair area. | ||
Repair wiring harness | |||
2 | Determine and mark positive line (pin 1 on connector plug of squib). | ||
3 | Repair wiring harness using end sleeves. | ||
| 000 588 00 84 00 Heat gun | ||
Make sure that the marked positive line is connected to the brown line of the repair wiring harness. | |||
Wire stripper | |||
Adapter | |||
Reflector | |||
Welding bead catcher | |||
4 | Protect repair point after line repair. | ||
| 000 588 00 84 00 Heat gun | ||
| Check | ||
5 | Check wiring harness after repair. | ||
Electrical connection kit | |||
Test box | |||
| Install | ||
6 | Install removed detachable parts in repair area. | ||
7 | Read out fault memory. | ||
| Model 906 | ||
| Model 907, 910 |
129 589 01 98 00
Welding bead catcher
220 589 01 99 42
Adapter
220 589 01 99 40
Wire stripper
220 589 01 99 41
Reflector
220 589 00 99 00
Electrical connection kit
000 589 00 21 00
Test box
Referenced documents
- ad0000d200004sd Connect STAR DIAGNOSIS and read out fault memory
- ad0000d200006ts Connect/disconnect diagnostic unit
- ah0000z001901a Notes on safety-relevant components
- ah0019p100003a Advantages of repairing wiring harnesses
- ah0019p100005a Assessment of damage in wiring harnesses
- ah0019p100007a Notes on soft soldering
- ah0019p100008a Notes on replacement of safety-relevant and special components
- ah0019p100010a Notes on soldering
- ah0019p100011a Notes on cable protection
- ah5400p000101a Information on preventing damage to electronic components due to electrostatic discharge
- ah9100z000010a Information, assessment and legal requirements when working with, handling and storing pyrotechnical components
- ar0019d010008a Protect repair area after cable repairs
- ar0019d010009a Repairing wiring harness using solder connectors
- ar5418d060001a Checking wiring harness
- as0000z000201a Risk of injury. Skin or eye injuries may result when handling hot or glowing objects.
- as0019z000101a Risk of injury caused by burns to skin and eyes. Risk of poisoning caused by inhaling fumes when working with heat-shrinkable tubing.
- as0019z000201a Risk of injury caused by burns to skin and eyes, risk of poisoning caused by inhaling fumes during soldering.
- as9100z000801a Risk of injury during testing and repair operations related to pyrotechnical components
- ws5400p0049b 000 588 00 84 00 Heat gun