Generator
Number | Designation | Engine | ||
BA15.40-P-1001-01H | Cable to generator terminal D+ | Nm | 8 | |
BA15.40-P-1002-01H | Cable to generator terminal B+ | Nm | 8 | |
P54.18-3363-06
1 Disconnect plug (1).
2 Disconnect connector (2) at turning angle sensor (3).
3 Disconnect connector (4) at gear motor (M17).
P54.00-2353-01
4 Disconnect connector (5).
P15.18-2084-06
5 Detach hose (7) at air filter box (6).
6 Unplug both connectors at EDG control module (N3/9).
Pull notch lever backwards at connectors and unplug connectors.
7 Unplug connector at preheating time control module (N14/2).
8 Unplug connector at intake air temperature sensor (B17).
9 Disconnect electrical lines at generator (G2).