ar4730p8253rt

Remove/install activated charcoal filter shutoff valve

Type ar · topic 47.30 · version 0100 · 2005-07-20

Applies to: MODELS 215 with CODE (494) USA version

Where it sits

Function group 1 Engine › 47 Fuel system, powertrain energy supply › 47.30 Fuel evaporation control system — Series 215

EinPAS 16 Fuel/power supply to engine › 16.10 Fuel supply › 16.10.13 Line/hose/valve — Series 215

AR47.30-P-8253RT

Remove/install activated charcoal filter shutoff valve

15.4.05

MODELS 215 with CODE (494) USA version

Remove/install activated charcoal filter shutoff valve

P47.30-2131-09

1 Electrical connector

Y58/4 Activated charcoal filter shutoff valve

3 Sealing rings

Remove/install

Danger!

Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contact with fuel.

No fire, sparks, open flames or smoking.
Pour fuels only into suitable and appropriately marked containers.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

1

Switch off ignition and remove the transmitter key from the EIS [EZS] control unit

On vehicles with Keyless Go, code 889: Press Keyless Go start/stop button repeatedly until the ignition is switched off.

Remove the transmitter key from the vehicle and store it in a location beyond its transmission range (min. 2 m).

2

Open fuel filler flap and filler cap

The fuel filler flap and tank cap are left open until the repair is completed, to ensure that pressure is not built up in the fuel tank.

Danger!

Risk of death caused by vehicle slipping or toppling off of the lifting platform.

Align vehicle between the columns of the lifting platform and position the four support plates at the lifting platform support points specified by the vehicle manufacturer.

AS00.00-Z-0010-01A

3

Raise vehicle with lifting platform

AR00.60-P-1000RT

4

Take off right rear wheel

Remove/install wheels, rotate if necessary

AP40.10-P-4050RT

5

Remove wheelhousing liner in right rear fender

AR88.10-P-1400RT

6

Detach electrical connector (1) from activated charcoal filter shutoff valve (Y58/4)

7

Turn activated charcoal filter shutoff valve (Y58/4) in counterclockwise direction (arrow A) and pull out of the activated charcoal canister (arrow B)

Installation: Make sure that the seal rings (3) are not damaged by the activated charcoal filter shutoff valve (Y58/4).

8

Install in the reverse order

Referenced documents