D42.60-1104-09
A Electric air compressor M57
B Compressed air drier with heater
C1 Compressed air reservoir V2 (separate compressed-air reservoir)
C2 Compressed air reservoir V3
C3 Compressed air reservoir V4
E2 Pressure switchB130
F Check valve
G1 Spring-loaded cylinder
G2 Spring-loaded cylinder
H1-H3 Test connections
K Intake line
D1 Pressure limiting valve
D2 Safety valve
D3 Overflow valve
D4 Relay valve
D5 Parking brake valve
E1 Pressure switch B118
D42.20-1102-01
1 Adjustment screw
C2 Compressed air reservoir V3
C3 Compressed air reservoir V4
D3 Overflow valve
H1-H2 Test connections
E2 Pressure switchB130
D42.20-1113-01
| Checking | ||
1 | Bleed parking brake system | ||
2 | Connect test kit to test connection (H1) at compressed air reservoir V3 (C2) | | |
3 | Fill parking brake system with compressed air until pressure regulator switches off | Compare cutoff pressure measured at test connection (H1) with specified value. If the measured cutoff pressure and specified pressure are different: | |
Install new pressure switch B130 (E2). | |||
| |||
4 | Lower the reservoir pressure of the parking brake system until the cut-in pressure of the pressure regulator is reached. | Compare cut-in pressure measured at test connection (H1) with specified value. If the cut-in pressure and specified value are different: | |
Install new pressure switch B130 (E2). | |||
| |||
5 | Check control range of pressure regulator between cut-in and cutoff pressure | Compare difference in pressure measured between cut-in and cutoff pressure with specified value. If the difference between the cut-in and cutoff pressure and specified value are different: | |
Install new pressure switch B130 (E2). | |||
| |||
6 | Remove test kit from test connection (H1) between check valve (F) and compressed air reservoir V3 (C2) | |
Parking brake
Number | Designation | Model 905 | ||
BA42.20-N-1012-01A | Pressure switch (B130) on pressure limiting valve T-piece | Nm | 15 | |
Test and adjustment values for service brake
Number | Designation | Model 905 | Model Series 905 up to | Model Series 905 from | |
BE42.10-N-1004-10A | Switching range | bar | 10.6 to 12.5 | - | - |
BE42.10-N-1017-10A | Activation pressure standby indicator lamp "(!)" Pressure switchB130 | bar | - | - | 11,0 (-0,4) |
BE42.10-N-1018-10A | Deactivation pressure electric air compressor pressure switch B130 | bar | - | - | 12,5 (-0,4) |
360 589 00 21 00
Test kit