355 589 00 33 00
Puller
717 589 00 31 00
Retainer wrench
Detach
1 | Mark installation position of drive flange (1) relative to the drive pinion. |
2 | Release collar nut. |
3 | Counterhold drive flange (1) with retainer wrench and unscrew collar nut. |
S35.30-4507-01
4 | Attach puller with screws M10x1x100 to drive flange (1). |
5 | Counterhold drive flange (1) with retainer wrench and remove drive flange (1) from drive pinion. |
6 | Check drive flange (1) for galling, and replace drive flange (1) if required. |
S35.30-4509-01
Attach
7 | Attach drive flange (1). |
Observe the marking for the installation position. |
8 | Counterhold drive flange (1) with retainer wrench and screw on new collar nut . |
S35.30-4507-01