001 589 53 21 00
Dial gage
363 589 02 21 00
Dial indicator holder
Determine the measure |
1 | Measure the dimension(A) of the bearing cap (2). |
Do not mount the transmission shaft (4) on the bridge holder (1). |
2 | Measure the dimension (B) on the bridge holder (1). |
3 | Determine the thickness of the lock ring (3). |
The thickness of the lock ring (3) is given by: |
Preferably use a lock ring (2) of thickness equal to or closer to the calculated thickness. |
4 | Install the transmission shaft (4) on the bridge (1). |
On the transmission shaft (4) the tapered roller bearings and the bearing cap (2) must already be installed. |
5 | Install the lock ring (3) on the bridge channel (1). |
Utilize appropriate tool. |
B35.30-0211-11
Check the axial play |
6 | Install the drive flange (5). |
To check the clearance, it is not necessary to install the sealing ring. |
7 | Install the collar nut (6). |
Tighten manually the collar nut (6). |
8 | Position the dial indicator holder (8) at the bridge (1) and support the dial indicator (7) on the top of the transmission shaft (4). |
9 | Move the transmission shaft (4) axially and check the end play. . |
If the value of the end play is not within the prescribed limits: | |
| |
Remove the collar nut (6), the drive flange (5), increase the thickness of the lock ring (2) and proceed from Step 5. |
B35.30-0214-11