AR27.19-S-0800A | Remove, install induction-type pulse generator (output rpm) | 29.11.95 |
ENGINES 601.970, 111, 611.980 in MODEL 638 with CODE (G40) Automatic transmission
Transmission installed
S27.19-2543-12
1 Torx bolt
2 Retaining clamp
3 Spacer
B91 Induction-type pulse generator
B91.1 Induction-type pulse generator connector
| Removing, installing | ||
| Ensure absolute cleanliness, use only lint-free cloths. | Contamination within the transmission represents a potential source of damage. | |
1 | Pull electrohydraulic control unit out of transmission housing | See Removing, installing electrohydraulic control unit (transmission installed). If the electrohydraulic control unit is not removed, the connector (X106) must not be disconnected. | |
2 | Detach cable of induction-type pulse generator connector (B91.1) from retaining clamp (2) | ||
3 | Unscrew torx bolt (1) | Ensure that the torx bolt (1) and spacer (3) do not fall into the transmission. | |
Spacer (3) is only installed with engines OM 611, OM 601 D23 LA and M111 E23. | |||
| |||
Torx socket wrench Tx27, 1/2" | |||
4 | Remove induction-type pulse generator (B91) and disconnect induction-type pulse generator connector (B91.1) | Induction-type pulse generator connector (B91.1) can only be disconnected after removing the induction-type pulse generator (B91). Lift clip (arrow) with screwdriver until the induction-type pulse generator connector (B91.1) can be disconnected. | |
5 | Install in the reverse order |
Transmission electrical system
Number | Designation | Model 638 with Series 111, 601.970, 611.980 engine | |
BA27.19-N-1001-02A | Induction-type pulse generator (output speed) at transmission | NM | 10 |
Commercially available tools
Referenced documents
- ar2719s0200a Remove/install electrohydraulic controller unit (transmission installed)