AR27.10-B-0171A | Pressure testing | 12.02.16 |
Automatic transmission 721.930, 721.931, 721.932, 721.933, 721.934, 721.936, 721.938, 721.939, 721.940
T27.10-0007-01
1 Pressure closing screw (main PH pressure)
2 Pressure closing screw (PD1 strangulation pressure)
3 Closing screw (PD2 pressure at the torque converter front)
4 Closing screw (pressure behind heat exchanger PD6 PD7)
5 Closing screw (retarder pressure PR3)
6 Closing screw (retarder regulating pressure PRR3)
T27.10-0008-01
Pressure gage connection
| Check | ||
Danger! | Risk of injuries on skin and eyes by hydraulic fluid high pressure expelled jets. Risk of poisoning by hydraulic fluid ingestion. | Before starting to work on the hydraulic system, relieve the system's pressure. Use suitable clothes and protection goggles. | |
1 | Remove the closing screws (1, 2, 3, 4, 5, 6) and attach the pressure gage | After having confirmed the pressure check, release the corresponding closing screw. The gearbox has to be at service temperature to enable the pressure check (the oil temperature, will have to be approximately from 80 to 90 °C), the oil level has to be correct and the oil must correspond to the specification. | |
| |||
| |||
| |||
2 | Checking the pressure | The nominal values of the respective pressures to be measured are corresponding to the determined operational conditions. | |
Pressure measuring table | |||
3 | Detach the gage and tighten the closing screws (1, 2, 3, 4, 5, 6) | Replace the sealing ring. | |
| |||
| |||
| |||
4 | Check the oil level and correct it if necessary | ||
| Automatic gearbox oil and filter change |
Complete automatic transmission
Número | Denominação | Automatic transmission 721.903/930/931, 721.932/933/934, 721.936/939/940, 721.941/945/947 | |||
BA27.10-B-1006-04D | Sealing plugs | For pressure control | Nm | 12 | |
123 589 04 21 00
Checking device
123 589 04 21 02
Coupling piece
Referenced documents
- ap2700b2702a Automatic transmission fluid and oil filter change
- ar2760b113001a Pressure measurement table
- as0000b001301a Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure.Risk of poisoning from swallowing hydraulic fluid.