AR26.50-P-0300A | Checking concentricity of flange | 23.10.98 |
MODEL 463 with TRANSMISSION 717.43# ## up to 6071380
P26.50-2046-01
| Perform this inspection if there are problems caused by wobble at coupling flange. | ||
| Check | ||
1 | Detach propeller shaft at transmission | ||
2 | Install measuring flange | Measuring flange | |
3 | Attach dial indicator and bracket to transmission housing | Dial indicator | |
Gage stand | |||
| The base plate can be used as an installation option for the measuring stand | ||
4 | Checking concentricity of flange | ||
If deviations are present | |||
Adjusting concentricity of flange | |||
| |||
Retainer wrench | |||
Puller | |||
Pin wrench socket | |||
Socket wrench bit | |||
5 | Attach propeller shaft to transmission | ||
| |||
Open-end wrench bit 13 mm | |||
Torque wrench |
Test specifications
Number | Designation | Model 460, 461, 463 | |
BE33.30-P-1002-02A | Total concentricity deviation of flange | mm | 0,07 |
Complete manual transmission
Driveshaft
363 589 02 21 00
Measuring flange
Dial indicator holder
Dial indicator
Retaining wrench
001 589 53 21 00
460 589 01 23 00
460 589 01 31 00
001 589 66 21 00
Open-end wrench bit 13 mm
Torque wrench
Puller
460 589 02 33 00
000 589 10 99 16
Pin wrench socket
115 589 01 07 00
Socket wrench bit
126 589 02 09 00
Referenced documents
- ar2650p030001a Adjusting concentricity of flange
- ar4110p005014c Detach, attach propeller shaft at transmission
- wf5850p333004a Base plate for measuring tripod