1 | Hydraulic pump |
2 | Pump fastening nuts |
3 | Gasket |
4 | Intermediate piece |
5 | Gasket |
W26.45-0092-11
| Remove/install | ||
Warning | Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure.Risk of poisoning from swallowing hydraulic fluid. | Depressurize hydraulic system completely before starting any work on it. Wear protective clothing and safety glasses. | |
1 | Remove the hydraulic pump (1) | Catch (and never re-use) the hydraulic fluid. | |
Installation: Utilize a new gasket (3) | |||
.Nuts attaching the hydraulic pump to the PTO | |||
2 | Remove the intermediate part (4) | Applied in version NA60 2c. | |
Installation: Utilize new gaskets (3) and (5). | |||
.Nuts attaching the hydraulic pump to the PTO | |||
3 | Install on the reverse order | ||
4 | Complete the hydraulic oil level in the power take-off reservoir | Follow the maker's instructions for service and maintenance. | |
5 | Check the gearbox oil level and correct if necessary | ||
| Gearboxes 712.623/631/632 and 715.054 | ||
| Gearboxes 712.362 and 712.451 |
Referenced documents
- ap2600b2601i Manual transmission - oil change
- ap2600b2610b Manual transmission - check oil level, correct
- as0000z001301a Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure.Risk of poisoning from swallowing hydraulic fluid.