ar2520l0070c

Bleed clutch actuation

Type ar · topic 25.20 · version 0101 · 2006-07-26

Applies to: ENGINE 904 in MODEL 668, 670 with CODE (B16) 2-circuit hydraulic brake/2-circuit compressed air brake with CODE (GF1) Transmission 710.6 (S 5-42)

Where it sits

Function group 2 Chassis › 25 Clutch › 25.20 Clutch actuation — Series 668 · Series 670 · Series 904

EinPAS 17 Drivetrain/axle › 17.15 Clutch › 17.15.5 Clutch operation — Series 668 · Series 670 · Series 904

AR25.20-L-0070C

Bleed clutch actuation

28.7.97

ENGINE 904 in MODEL 668, 670
with CODE (B16) 2-circuit hydraulic brake/2-circuit compressed air brake
with CODE (GF1) Transmission 710.6 (S 5-42)with chassis no.: as of 099978

Bleed clutch actuation

L25.20-0004-12

1 Expansion reservoir

2 Protective cap

3 Vent hose

4 Bleeder valve

Bleeding

Danger!

Risk of poisoning from swallowing brake fluid. Risk of injury from brake fluid coming into contact with skin and eyes.

Pour brake fluid only into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling brake fluid.

AS42.50-Z-0001-01A

1

Connect connection line of bleeder unit to expansion reservoir (1)

Bleeder unit, pneumatic

*WH58.30-Z-1001-24A

Bleeder unit, electric

*WH58.30-Z-1002-24A

Notes on handling brake fluid

All models

AH42.50-P-0001-01A

2

Switch on bleeder and open the stop lever.

The pressure in the bleeder unit should not fall below 2.0 bar.

3

Remove the protective cap (2) and attach the discharge hose (3) to the bleed valve (4)

4

Open the bleed valve (4) and allow the brake fluid to continue flowing until no more air bubbles are visible in the discharge hose (3)

Open bleeder valve by at least 45°.

5

Close the bleed valve (4)

6

Remove discharge hose (3) and put on protective cap (2)

7

Close the stop lever and remove the bleeder

Take care that the bleeder unit is not under pressure, if so then lower pressure in bleeder unit.

8

1Correct fluid level in expansion reservoir (1).

9

Perform function check

If the clutch-release mechanism fails to provide satisfactory performance, repeat the bleeding operation.

10

Check bleed valve (4) for leakage

Commercially available tools

Number

Designation

WH58.30-Z-1001-24A

Bleeder unit, pneumatic

WH58.30-Z-1002-24A

Bleeder unit, electric

Referenced documents