ar2010d3000we

Remove/install coolant pump switchover valve

Type ar · topic 20.10 · version 0100 · 2016-05-10

Applies to: Engine 651 in model 906

Where it sits

Function group 1 Engine › 20 Engine cooling system › 20.10 Coolant pump, coolant thermostat — Series 651 · Series 906

EinPAS 15 Engine › 15.25 Engine cooling system › 15.25.13 Line/hose/valve — Series 651 · Series 906

AR20.10-D-3000WE

Remove/install coolant pump switchover valve

19.04.2016

Engine

651 in model 906

Remove/install coolant pump switchover valve

1

Vacuum hose

2

Vacuum hose

3

Lock

4

Electrical connection

Y19/10

Coolant pump switchover valve

S20.20-4524-11

Remove/install

1

Remove engine cover

AR01.10-D-2405WE

2

Unclip vacuum hose (1)

3

Remove vacuum hoses (2)

Installation: Note assignment of the vacuum hoses (2).

4

Remove coolant pump switchover valve (Y19/10)

To do this, release lock (3).

5

Disconnect electrical connection (4)

6

Install in the reverse order

Check

Danger !

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

7

Check for leaktightness with engine running

Visual inspection only.

Referenced documents