D20.40-1012-06
1 Coolant pump
2 Belt pulley
3 Bolts
4 Bolts
5 Bolt
6 Gasket
| Remove/install | ||
Danger! | Risk of injury to skin and eyes caused by scalding from contact with hot coolant spray. Risk of poisoning caused by swallowing coolant. | Do not open cooling system unless coolant temperature is below 90°C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. Wear protective gloves, protective clothing and safety glasses. | |
1 | Remove fan shroud | ||
2 | Loosen bolts (3) | ||
3 | Remove poly-V belt | ||
4 | Remove bolts (3) and belt pulley (2) | ||
5 | Remove bolts (4, 5) and coolant pump (1) | Collect coolant in a suitable container. | |
Installation: Clean sealing surface on coolant pump (1) and on timing case cover. Replace gasket (6). | |||
| |||
6 | Install in the reverse order |
Coolant pump, coolant thermostat
Referenced documents
- ar1322d1202ng Remove/install poly-V belt
- ar2040d6800ng Remove/install fan shroud
- as2000z000101a Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant.