P15.40-2339-05
0100 STAR DIAGNOSIS
X11/4 Data link connector
| Check | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
| Information on preventing damage to electronic components due to electrostatic discharge | ||
| Notes on battery | ||
1 | Check condition of the battery | Assess the results, replace battery if required. | |
2 | Connect up STAR DIAGNOSIS (0100) to data link connector (X11/4). | ||
| Connect up STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system | |||
Danger! | Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns during starting procedure or when working near the running engine | Secure vehicle to prevent it from moving by itself. | |
3 | Check alternator using STAR DIAGNOSIS (0100) | Only perform tests when engine at its normal operating temperature. The checking procedure is menu-assisted: - actuations - alternator diagnosis | |
STAR DIAGNOSIS diagnosis system | |||
4 | Disconnect STAR DIAGNOSIS (0100). | STAR DIAGNOSIS diagnosis system |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ah5400p000101a Information on preventing damage to electronic components due to electrostatic discharge
- ah5410p000101a Notes on battery
- ah5410p000101a
- ar5410p1129v Check condition of battery
- as0000z000501a Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.
- as5410z000101a Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of