D14.40-0008-08
1 | Metering device | 3 | Electrical connector | |
2 | O-ring | 4 | SCR AdBlue pressure sensor |
| Remove/install | ||
1 | Remove maintenance cover | ||
2 | Disconnect electrical connector (3) from the AdBlue pressure sensor SCR (4) | ||
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
3 | Remove AdBlue pressure sensor SCR (4) from the metering device (1) | ||
Notes on use, material properties and handling of AdBlue® | |||
Note the O-ring (2). | |||
SCR AdBlue pressure sensor to metering device | |||
4 | Install in the reverse order |
Referenced documents
- ah1440n000101a Notes on use, material properties and handling of AdBlue®
- as1440z000101a Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue