P30.20-2206-08
Shown on model 246.2 |
1 | Engine cover | 5 | Charge air pipe | B17/7 | Charge air temperature sensor upstream of throttle valve | ||
2 | Air filter housing | 6 | Coolant line | G3/2x1 | Electrical connection for oxygen sensor upstream of catalytic converter | ||
4 | Screw/bolt | 7 | Screw/bolt | M16/6 | Throttle valve actuator |
| Remove/install | ||
1 | Switch off ignition | ||
2 | Remove engine cover (1) | ||
3 | Remove air filter housing (2) | ||
4 | Unclip electrical connection for oxygen sensor upstream catalytic converter (G3/2x1) from bracket and disconnect | ||
5 | Unclip electrical line for oxygen sensor upstream of catalytic converter from bracket and place to one side | ||
6 | Remove charge air temperature sensor upstream of throttle valve (B17/7) | ||
7 | Disconnect electrical connection from throttle valve actuator (M16/6) | ||
8 | Unclip electrical line from throttle valve actuator (M16/6) and lay down to side | ||
9 | Remove screw/bolt (4) for charge air pipe (5) at bracket | ||
10 | Detach coolant line (6) to vacuum pump and engine suspension lug | ||
11 | Remove screw/bolts (7) | Bolt, throttle valve actuator to charge air distributor | |
12 | Remove throttle valve actuator (M16/6) upwards | Installation: Replace seals. | |
13 | Install in the reverse order | ||
14 | Connect diagnostic system; read out fault memory. | ||
|
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ar0910p1150mt Remove/install air filter housing
- ar0910p1150mta Remove/install air filter housing